ARM6DC Series Photovoltaic solar type dc mccb 700VDC/1000VDC/1500VDC 250A 2/4 Poles

ARM6DC

ARM6DC Series Photovoltaic solar type dc mccb 700VDC/1000VDC/1500VDC 250A 2/4 Poles

Rated Current: 63A、80A、100A、125A、140A、160A、180A、200A、225A、250A

Number Of Poles: 2P/4P

Rated Working Voltage: 1000V/DC1500V

    MCCB Highlights


    1. ARM6DC series moulded case circuit breakers are applicable to the centralized photovoltaic power station system. The DC input voltage for 2P is 500~1000V, and the DC voltage for 4P can be up to 1500V.and 

    2. ARM6DC small ampere has the structural characteristics of high protection accuracy and long service life.

    The mechanism components and release are designed and optimized on the M3 structure platform, ensuring the reliability and tripping accuracy. Mechanical life: 10000 times, electrical life: 2000 times

    ARMdc

    Main performance index of ARMDC series circuit breaker

    Model ARM6DC-250
    Rated current In (A) 63A、80A、100A、125A、140A、160A、180A、200A、225A、250A
    Number of poles (P) 2P 4P
    Rated working voltage Ue (V) 1000VDC 1500VDC
    Rated ultimate short-circuit breaking capacity Icu (kA) 40kA 20kA
    Rated service short-circuit breaking capacity Ics (kA) 40kA 20kA
    Rated insulation voltage Ui (V) 1500V
    impulse withstand voltage Uimp (kV) 12kV
    Mechanical life (time) 7000
    Electrical life (time) 1000
    Arcing distance (mm) Upper/lower:100/0
    Left/right/front/rear: 0/0/0
    Overall dimension (mm) w*l*h W 89.5 142.5
    L 200 200
    H 108
    108

    Overall and installation dimensions

    ARM6DC-250-2300

    ARM6DC-250-23004ws

    ARM6DC-250-4300

    ARM6DC-250-4300q2z

    Installation safety clearance of circuit breaker

    1. For incoming line mode, the lower incoming line will not affect the normal use of the product and will not reduce 
    the capacity.
    2. Fixing method: base plate and hollow plate.
    3. See the figure for safety distance. 

    ARM6DC-250-2300

    ARM6DC-250-2300aa7uz

    Minimum distance between circuit breaker and base plate, top plate and side plate

    ARM6DC-250-2300abqv6

    Minimum distance between circuit breakers in row

    ARM6DC-250-2300abczf2

    Minimum distance between circuit breakers in vertical row

    Code
    Min. distance (mm)
    A 0
    B 35
    C 40
    D 55

    1. Connection without insulation
    2. Insulated cable
    3. Insulated terminal

    ARM6DC-250-4300

    ARM6DC-250-4300aavri

    Minimum distance between circuit breaker and base plate, top plate and side plate.

    ARM6DC-250-4300abtzc

    Minimum distance between circuit breakers in row

    ARM6DC-250-2300abc18a

    Minimum distance between circuit breakers in vertical row

    Code
    Min. distance (mm)
    A 10
    B 35
    C 0
    D 13
    E 40
    F 55

    1. Connection without insulation
    2. Insulated cable
    3. Insulated terminal