ARM3E Series electronic type adjustable type Molded Case Circuit Breaker 400V/690V 400A 3/4 poles Built in LSIG Trip Unit

ARM3E

ARM3E Series electronic type adjustable type Molded Case Circuit Breaker 400V/690V 400A 3/4 poles Built in LSIG Trip Unit

Rated Current : 160A、180A、200A、225A、250A、280A、315A、400A

Number Of Poles : 3P / 4P

Rated Working Voltage : 400V/690V

    MCCB Highlights

    Advantages and highlights of welding process equipment for MCCB Electronic type hardware parts
    1. Side heating resistance welding process: the silver spot welding transfers heat from copper heating to silver spot welding. The silver spot has no electrical corrosion damage, which does not cause the silver spot surface to fade and become soft. It retains the original state of the silver spot. The contact has no damage, and the welding consistency is good, which increases the mechanical life and electrical life of the contact point by 15%.

    2. The infrared temperature control technology is used to precisely control the welding parameters, which ensures the welding quality and greatly improves the service life of the product by 50%.

    ARM3e

    Main performance index of ARM3E series circuit breaker

    Model ARM3E-400
    Rated current In (A) 160A,180A,200A,225A, 250A,280A,315A,
    350A,375A,400A
    Rated current of frame size Inm (A) 400A
    Usage category Category B
    Rated ultimate short-circuit breaking capacity level L M H
    Number of poles (P) 3P 3P 3P 4P 4P
    Rated working voltage Ue (V) 400V
    Rated ultimate short-circuit breaking capacity Icu (kA) 50kA 65KA
    100KA
    Rated service short-circuit breaking capacity Ics (kA) 50kA 42KA 65KA
    Rated short-time withstand current Icw (kA/1S) 5KA/1s
    8KA/1s
    Rated working voltage Ue (V) 690V
    Rated ultimate short-circuit breaking capacity Icu (kA) 20KA
    Rated service short-circuit breaking capacity Ics (kA) 15KA
    Rated insulation voltage Ui (V) 1000V
    Rated impulse withstand voltage Uimp (V) 8kV
    Mechanical life (time) 4000
    Electrical life (time) 1000
    Arcing distance (mm) ≯100
    W*L*H (mm) 654dc7ellx 3P 150*258*111
    4P 200*258*111
    package 3p 198*277*177
    package 4p 250*280*180
    weight 3P 5712g
    weight 4P 7808g

    Overall and installation dimensions of circuit breaker

    Circuit breaker 400 frame size installation safety interval

    ■ Front panel wiring (3P, 4P)
    X-X, Y-Y are the center of three-pole circuit breaker

     
    Model C D
    ARM3R-630(L/M/H)
    ARM3-400(C/L/M/H)
    ARXM3-400L/M/H
    40 59
    ARM3L-400(L/M/H)
    ARM3ER-630(L/M/H) ARM3E-400L/M/H
    26 49


    Circuit breaker 400

    ■ Rear panel wiring (3P, 4P)
    X-X, Y-Y are the center of three-pole circuit breaker

    Circuit breaker 400

    ■ Plug-in rear panel wiring (3P, 4P)
    X-X, Y-Y are the centers of three-pole circuit breake